Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Comparison of Direct and Indirect Techniques to Develop Customized Implant Impression Copings: A Pilot Study
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 35 , Issue 4
July/August 2015

Pages 525–531


Comparison of Direct and Indirect Techniques to Develop Customized Implant Impression Copings: A Pilot Study

Diego Velásquez, DDS, MSD/Juan C. Duran Yaneth, DDS/J. Felipe Aguirre Kaliks, DDS


PMID: 26133142
DOI: 10.11607/prd.2118

The aim of this pilot study was to compare a direct and an indirect technique for fabricating customized impression copings. The accuracy of these techniques to capture the tissue contours that have been developed using implant-supported fixed interim restorations (ISFIRs) in single implants for their esthetic value were evaluated. Five patients presenting with maxillary central incisor ISFIRs were enrolled in the study. Customized impression copings were fabricated using a direct and an indirect technique. Specimens of experimental (direct and indirect technique) and control groups (ISFIR) were compared in terms of linear measurements on their buccolingual (BL) and mesiodistal (MD) dimensions at three different levels: platform, middle, and gingival margin. Statistically significant differences were detected between the control group and the direct technique specimens on both the gingival margin and middle levels (P < .05). Between the direct and indirect techniques, statistically significant differences were found in their MD and BL dimensions at the gingival margin level (G-MD, G-BL) and the buccolingual dimension at the middle level (M-BL) (P < .05). The indirect technique used for the fabrication of customized implant impression copings seems to be more accurate in capturing the profile of the ISFIR at all three levels (platform, middle, and gingival margin). The direct technique is accurate only at the platform level.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help